Multisizer 3 Coulter Counter

Using the Coulter Principle, also known as ESZ (Electrical Sensing Zone), the Multisizer 3 COULTER COUNTER provides number, volume, mass and surface area size distributions in one measurement, with an overall sizing range of 0.4 µm to 1,200 µm. Its response is unaffected by particle color, shape, composition or refractive index.

The Coulter Principle is the absolute leading technology in high resolution and accuracy and it is further enhanced in the Multisizer 3 by using a Digital Pulse Processor (DPP).

Documentation and Application Notes

 

 

 

Choose a Multisizer 3 COULTER COUNTER Model

Tech Docs Part Number Product Name Description List Price Buy
A88098
20.1" Display

-

Buy
8321317
Ethernet interface

-

Buy
8321309

-

Buy
6605697
Measures particles as small as 0.4 μm • Easy to operate. Instrµment completely controlled through the computer with user-friendly software. • Digital Pulse Processor. Real-time measurements. Suitable for both aqueous and organic electrolytes. • Environmentally friendly, mercury-free metering system. • New aperture system (no grease) makes it easy to reconfigure for a desired size range. • Resolution can be selected from 4 to 300 channels at any selected range. • Multiple security levels.Enables 21 CFR Part 11 Compliance. • Software not license restricted. Can be installed on multiple computers for offline processing

-

8546719
Isoton II 20L

-

Buy
A35473
Accuvettes, 25mL

-

6602796
10 µm Standard

-

Buy
6602798
L20 Standard

-

6600708

-

A36394
100 μm aperture tube

-

Features

Multi-Parameter Analysis

  • Digital Pulse Processor (DPP) samples signals millions of times/second for accurate particle counts/size, volume & shape characteristics
  • Highest resolution available for particle size distributions by volume measurement
  • DPP allows recalculation of original data over narrower range for significantly enhanced resolution of targeted range

Flexible Easy Data Analysis

  • Store & save pulse data without information loss
  • Re-run data at any time using different parameters
  • Wizards for easy test setup & reporting
  • SOMs/SOPs stored for consistent operation of standard tests & data sharing across sites/labs

Quality Assurance

  • User defined SOPs
  • Multiple security levels for 21 CFR Part 11 compliance
  • Trending capability for quick easy process monitoring
  • Certification Program to ensure instrument performance
  • V-Check (IQ, OQ, PQ) instrument validation

Calibration and Resolution

  • Automatic calibration for consistency & confidence in results
  • Calibration status can be verified at any time

Product Specifications

Sample Volume Range 3.00|400.00|mL
Particle Size Analysis Range 4.00|1,200.00|μm / 4|1200|μm
Item Specifications Referenced 6605697

Documentation

  • Filter by:

Technical Documents